Before choosing a UK SIP trunking provider, ask for written answers on number porting, PBX compatibility, call capacity, security, failure handling, support, contract terms, reporting and leaving the service. A useful answer names the configuration, the evidence and the person responsible. A feature tick on its own tells you very little.
The awkward questions usually appear after the order: who handles a rejected number transfer, whether the backup route accepts inbound calls, or why a phone-system fault sits between two support desks. Use these 15 SIP trunking provider questions before signing, then turn the answers into an agreed test and handover plan.
This guide is for UK businesses comparing proposals, particularly those keeping an existing phone system. It does not rank providers. Its verification matrix translates public regulatory guidance, security principles and technical standards into evidence you can request for your own deployment.
If the proposed trunk will connect to Teams Phone, use our Microsoft Teams Direct Routing requirements guide to check licensing, certified SBC support, tenant responsibilities and emergency calling alongside the carrier proposal.
Start With the Service You Actually Need
SIP trunking connects a compatible business phone system, usually a private branch exchange (PBX), to a provider’s voice service over an IP connection. SIP is the protocol used to establish and manage sessions; buying a trunk does not automatically replace your PBX or include a collaboration platform. RFC 3261, the SIP specification, describes the protocol rather than a provider’s commercial package.
If you intend to keep your PBX, start with the connection, compatibility and support boundary. Vertu Connect’s SIP trunking page is the relevant service starting point. If the project also includes staff messaging, meetings or a new calling platform, review the unified communications options and our UCaaS vs CCaaS vs VoIP guide to separate those requirements.
Give each shortlisted provider the same brief: sites, existing PBX model and software version, numbers to retain, peak simultaneous calls, required call flows, connectivity and equipment that still uses a telephone line. That makes the answers comparable without pretending every business needs the same package.
Porting and Cutover
1. Can You Port Every Number We Need to Keep?
Ask the provider to check the actual number list, not just confirm that it offers porting. Include main numbers, direct-dial numbers, complete ranges and any numbers held on separate accounts. Request the account details and authorisation documents needed, any limitations, charges and the owner of a rejected request.
Ofcom explains number portability as the facility for keeping numbers when changing provider. That regulatory context is useful, but it does not confirm the readiness of your particular transfer. Keep cancellation and porting as separate actions until the providers agree the sequence.
A useful answer contains: a checked number inventory, outstanding dependencies and a named porting contact. “You can keep your numbers” is the beginning of the conversation.
2. What Happens if the Port Is Delayed or the Cutover Fails?
Request a cutover plan covering the change window, expected disruption, test calls, escalation and the decision to stop or proceed. Ask what remains available before the port completes and what can realistically be recovered afterwards. Do not accept “rollback” without an explanation of what can be reversed and by whom.
Check whether changing or ceasing a line affects broadband, alarms, entry systems or other services. Our PSTN switch-off readiness guide provides the wider inventory and dependency checks. The SIP order should fit into that plan rather than becoming a separate deadline.
A useful answer contains: an agreed change plan, recovery options, contact details and acceptance criteria for each critical number.
Interoperability and Capacity
3. Is Our Exact PBX Configuration Supported?
Name the PBX model, software version, licences, firewall and any session border controller (SBC). An SBC manages the boundary between voice systems; ask whether one is required, where it sits and who maintains it. Request the provider’s supported configuration and identify who handles faults involving the PBX maintainer.
“SIP compatible” does not establish that your transfer, caller-ID and routing requirements work in the proposed configuration. Get a test plan for the combination you will actually deploy, including any remote sites.
A useful answer contains: version-specific support, configuration requirements, equipment costs and clear responsibility for updates.
4. Which Call Flows Will You Test Before We Accept the Service?
For the wording and menu checks, use our auto-attendant phone scripts for UK businesses. Verify that every advertised choice reaches the intended destination before accepting the call flow.
Test inbound and outbound calls, direct-dial routing, caller ID, hold, attended and unattended transfers, voicemail, queues and out-of-hours handling. Include keypad input through menus, calls to mobiles and any workflow your reception or customer-service team relies on.
Keypad signalling deserves its own check. RFC 4733 defines carriage of telephone events, including DTMF digits, in RTP packets. Ask which method the proposed systems use and prove that the receiving menu recognises it. Two people being able to speak does not complete the acceptance test.
A useful answer contains: a shared test sheet with expected results, the actual configuration and a process for resolving failures before sign-off.
5. How Are Simultaneous Calls Sized and Changed?
Count concurrent calls rather than employees. Ask how incoming and outgoing calls share capacity, whether forwarding or transfers consume extra channels, what happens at the limit and how quickly capacity can be changed. Check any burst arrangement, charges and commitments in writing.
For connectivity, request a calculation based on the selected codec, protocol overhead, busiest call period and other traffic. Ask who will assess packet loss, jitter and delay on the actual path. A broadband download-speed figure alone is not the acceptance criterion.
A useful answer contains: a capacity assumption, a bandwidth requirement, overflow behaviour and the commercial effect of adding or removing channels.
Security and Fraud Controls
6. What Is Encrypted, and Where Does That Protection Stop?
Separate call signalling from audio. SIP over TLS protects signalling on the relevant connection; SRTP provides protection for media traffic when implemented and configured appropriately. The use of TLS on one SIP connection does not establish protection across every subsequent connection or for the audio itself.
Ask the provider to describe the route from your PBX or SBC to its service, the controls used and where encryption ends. Include certificate management, supported configuration and what happens when calls reach another network. NCSC’s data-in-transit principle supplies a useful framework for questioning protection across service boundaries; it is not a certification of a SIP supplier.
A useful answer contains: a documented protection boundary, configuration responsibilities and explicit limitations. “Private network” and “encrypted” need an explanation.
7. How Do You Limit Fraud and Control Administrative Access?
Ask about destination restrictions, spend limits, unusual-use alerts, trunk authentication and access to the management portal. Check whether multi-factor authentication and separate administrator roles are available, which controls are enabled by default and who can change them.
Then ask what happens overnight. Does a threshold send an alert, block a destination or suspend calling? Who receives it, who can restore service, and what charges remain payable? A spend limit should not be treated as a guaranteed cap unless the contract explicitly says how it operates.
A useful answer contains: default controls, alert recipients, intervention rules and the contractual treatment of disputed or fraudulent traffic.
Resilience and Emergency Calling
8. What Happens When the Connection, PBX or Provider Platform Fails?
Ask three separate questions. If your access connection fails, can new inbound calls reach another site or mobile? If the PBX or SBC fails, is a different route triggered? If the provider platform fails, which alternative remains available? Request the trigger, dependencies and restoration process for each case.
Separate new-call routing from preserving a call already in progress. Also check outbound calling during the fault: forwarding incoming calls is not the same as keeping the office able to dial out. Agree a controlled test and record both failure and restoration behaviour. Our business VoIP reliability guide introduces the connection and power dependencies behind this discussion.
A useful answer contains: a failure-by-failure plan, testable behaviour and any shared dependency between the primary and backup arrangements.
9. How Will Emergency Calls and Location Information Work?
Ask how 999 and 112 calls are supported, what location information is associated with each site or number, and who updates it when people or equipment move. Include remote users, backup routes and any restrictions during loss of power or connectivity.
Ofcom’s digital-landline guidance explains the dependence on mains power without backup. Its household backup discussion does not establish what is included in your business SIP contract. Ask for the complete power plan for routers, switches, the PBX, SBC and endpoints, and agree the emergency-calling fallback. Use the provider’s authorised validation process; do not make unarranged emergency test calls.
A useful answer contains: the documented location process, limitations, power responsibilities and an agreed method of verification.
Support and Service Commitments
10. Who Owns a Fault Across Suppliers?
A calling fault can involve the carrier, access provider, firewall, SBC or PBX. Ask who leads diagnosis when these are supplied by different companies. Find out what evidence you must collect, who contacts the other suppliers and whether your PBX maintainer needs a separate support agreement.
Check support hours, the route for urgent incidents, escalation contacts and update frequency. Distinguish acknowledgement, an engineer starting work, a workaround and restoration. Those are different commitments.
A useful answer contains: one agreed escalation process, named responsibility at each boundary and a worked explanation of how a cross-supplier incident is handled.
11. What Does the Service Commitment Actually Cover?
Read the proposed service-level agreement alongside the design. Ask which components and call functions it covers, how performance is measured, what counts as an incident, and which maintenance windows or customer-side faults are excluded. Check reporting, claim deadlines and any remedies.
A platform availability commitment may leave questions about the access connection, local equipment or particular call routes unanswered. Map the commitment to the failures in question eight rather than comparing headline percentages without context.
A useful answer contains: the applicable service schedule, measurement boundary, exclusions, escalation terms and remedy process.
Contract and Commercial Scope
12. What Is Included in the Quote, and What Can Change?
Request separate lines for channels, numbers, call usage, porting, installation, equipment, connectivity and support. Check minimum spend, billing increments, excluded destinations, forwarded-call charges and the treatment of VAT. Ask what any “unlimited” allowance excludes.
Record the initial term, renewal process, notice period, price-change mechanism and early-termination charges. Establish whether adding channels or sites starts a new commitment. Some regulatory protections depend on customer category and service scope; Ofcom’s General Conditions overview is the reference point, rather than an assumption that all consumer terms apply to your business.
A useful answer contains: an itemised quotation and the contract schedules that explain changes over the life of the service.
Reporting and Handover
13. Which Reports and Logs Can We Access?
Where Teams is involved, use our Teams call queue history and reporting guide to separate a shared callback list from queue analytics and carrier logs. Ask which layer each proposed report actually covers.
Request a sample call-detail export and ask what it shows: timestamps and time zone, numbers, duration, call outcome and charges. Check whether failed attempts are included. A billing record may not explain why audio broke up; ask separately about diagnostic access and the process for requesting traces.
For administrative access and security events, ask about audit logs, alerts, retention and export formats. NCSC’s audit-information principle explains why knowing the available data, format and retention period matters when investigating incidents. Agree access permissions and secure handling of logs; do not assume call recording is part of the trunk service.
A useful answer contains: sample outputs, access rights, retention periods and a documented route to technical evidence.
14. What Will We Receive at Handover?
Ask for the final number inventory, routing configuration, capacity, accepted test results, support contacts and change procedure. Record who owns each administrator account and how credentials are transferred securely. Include renewal and notice dates in the operational record.
Decide who checks the first bills and retests backup arrangements after changes. The proposal explains what was intended; the handover should describe what was installed and accepted.
A useful answer contains: a defined handover pack, customer access arrangements and an owner for ongoing checks.
Exit Planning
15. How Can We Leave Without Losing Numbers or Useful Records?
Ask about porting away before you join. Request the account and number information a future provider will need, assistance available, charges, notice and the sequence for porting and ceasing services. Confirm the treatment of number ranges and services bundled into the same contract.
Establish which logs and configurations you can export, the format, the access deadline and what happens to retained data after termination. A right to retain numbers does not settle every contractual or operational step. Assign an owner for the exit plan while the service details are still fresh.
A useful answer contains: a documented exit process, export options and a cancellation sequence that can be checked with the gaining provider.
A Source-Linked Verification Matrix
Copy this matrix into your procurement notes. For every row, record the provider’s answer, evidence link or document, configuration, responsible person, check date and unresolved action. Use confirmed, conditional, unresolved or not applicable; record the reason for each status. Public sources explain the questions. Only deployment-specific evidence can confirm the answers.
| Questions | Evidence to Request | Public Reference or Verification Route |
|---|---|---|
| 1–2: Porting | Checked number list, dependencies, cutover and recovery plan. | Ofcom number portability; provider-confirmed port arrangements. |
| 3–5: Interoperability and Capacity | Supported versions, call-flow results, capacity assumptions and overflow behaviour. | SIP standard and telephone-event standard; actual configuration tests. |
| 6–7: Security | Protection boundaries, default controls, administrative access and fraud response. | NCSC transit protection and SRTP standard; provider security design and terms. |
| 8–9: Resilience | Failure and restoration results, power plan and emergency-location process. | Ofcom digital-landline context; agreed tests and business-service documentation. |
| 10–12: Support and Contract | Escalation ownership, service schedule, exclusions, itemised quote and renewal terms. | Ofcom regulatory overview; the specific contract and service commitments. |
| 13–14: Reporting and Handover | Sample exports, retention, access rights and the final configuration record. | NCSC audit-information guidance; sample outputs and handover specification. |
| 15: Exit | Port-out requirements, export deadlines, charges and the cessation sequence. | Ofcom number portability; the provider’s exit procedure and contract. |
Follow One Failure Through the Proposal
Hypothetical example: an office keeps its PBX and wants calls diverted to a second site when its access connection fails. The proposal says “automatic failover”. Before accepting it, ask what detects the fault, whether new calls reach the second site, what happens to active calls and how staff place outbound calls.
Now check the second site. Does it share the affected connection, equipment or provider dependency? Who restores the normal route, and who verifies it afterwards? Put the agreed answers into a controlled test. The result may be acceptable even if active calls disconnect, provided that limitation is understood and fits the business requirement.
This is the final buying check: can you trace one important call from the number and contract through the equipment, failure response, support desk and eventual exit? If the answers stop at a supplier boundary, resolve that boundary before signing.
Once you have provider answers, use the SIP trunking migration checklist to record number-porting inputs, capacity assumptions, failure tests and cutover evidence. Its downloadable worksheet separates the stop plan before activation from recovery after the numbers have moved.
Use the Questions in Your Provider Discussion
Take your number list, PBX details, busiest call periods and required fallback arrangements to a consultation with Vertu Connect. Use the same questions to establish the proposed configuration, supporting evidence and responsibilities before deciding whether it fits your business.
Frequently Asked Questions
Is SIP Trunking the Same as a Hosted Phone System?
No. SIP trunking connects a compatible phone system to a provider’s voice service. A hosted phone system supplies phone-system functions as a service. Confirm which equipment, licences and management responsibilities are included in the proposal.
Can We Keep Our Existing Business Numbers?
Number portability allows numbers to be retained when changing provider, but the provider needs to check your actual numbers, ranges, account details and transfer arrangements. Get a written porting plan and agree the cancellation sequence before ceasing any service.
How Many SIP Channels Do We Need?
Base the requirement on peak simultaneous calls and the provider’s capacity rules, rather than staff headcount. Check incoming and outgoing capacity, forwarding and transfer behaviour, overflow, and the terms for changing channel numbers.
Does SIP Over TLS Encrypt the Audio?
Not by itself. TLS protects SIP signalling on the relevant connection. Media protection needs a separate mechanism, such as correctly configured SRTP. Ask the provider to document both protections and where they end.
Will SIP Calls Work During a Power or Internet Outage?
That depends on the design. Ask separately about backup power, access failover, alternative inbound routes and outbound calling. Check what happens to active calls and how emergency calling works during the fault. Agree controlled failure and restoration tests.
What Evidence Should We Request Before Signing?
Request a checked number inventory, supported PBX configuration, call-flow and failure test plan, security boundaries, itemised quote, service schedule, support ownership, sample reports and an exit procedure. Record unresolved conditions and the person responsible for closing them.
Sources and Review Scope
Prepared on 7 October 2026 using the public Ofcom, NCSC and RFC Editor sources linked in this guide. The matrix is an editorial procurement tool, not a provider audit, ranking or technical certification. NCSC’s cloud principles are used as a security-question framework; the protocol standards explain mechanisms rather than proving any supplier’s implementation. No hands-on service testing is claimed. Recheck service documentation, contract terms and official guidance before ordering and cutover.
Join The Conversation
If we need call recording, does that normally sit with the PBX, or is it a separate service we'd bolt on alongside the trunk?
Recording rarely comes with the trunk itself; a SIP trunk just carries calls. It usually sits in the PBX, which often has built-in or licensed recording, or as a separate service tapping the call path at the SBC. The right choice depends on retention, search and compliance needs, so ask where audio is stored and how it handles transfers.