A SIP trunking migration checklist should confirm seven things before live numbers move: the number inventory, porting records, peak call capacity, phone-system compatibility, connectivity and power dependencies, emergency-calling arrangements, and a tested cutover and recovery plan. Give each check an owner, evidence and a decision. A tick without a test result or a provider-confirmed answer is still an assumption.
The call to reception may work perfectly while a direct-dial number rings the wrong team, a transfer fails or the backup connection cannot place outbound calls. Those are the details this checklist is designed to catch.
Use it if you are preparing to migrate to SIP trunking or move an existing trunk to another provider. It is a vendor-neutral worksheet for UK businesses, particularly those retaining a PBX. The downloadable version has space for your own records; the checks below explain what to gather and what needs proving.
Set the Scope Before You Book the Change
For a migration into Teams Phone, review the Microsoft Teams Direct Routing requirements before setting the cutover window. The guide separates Microsoft prerequisites from decisions about SBC operation, routing policies, emergency calling and support ownership.
Write down the sites, departments and services affected. Record your PBX make, model, software version, SIP licences, firewall and any session border controller (SBC). An SBC manages the boundary between voice systems; confirm whether your proposed design needs one and who maintains it.
SIP controls the establishment and management of sessions. The IETF SIP specification describes the protocol; it does not establish that two particular products will interoperate. Ask for support for your exact versions, codecs, authentication, number formats and call flows.
Vertu Connect’s SIP trunking service page is the starting point for a trunk enquiry. If the project includes a new staff calling and collaboration platform, separate that scope using the unified communications options. For Microsoft Teams calling, confirm the specific calling arrangement, licences and integration rather than assuming a SIP trunk alone supplies them.
Name the migration lead, porting contact, PBX maintainer, network owner and business tester. Give one person authority to approve the cutover, with an alternate if they are unavailable. Get support availability and escalation routes agreed for the actual change window.
Build a Number Inventory That Includes the Quiet Lines
Start with bills, provider records and PBX configuration, then reconcile them with the people who use the numbers. Include main numbers, direct dial-in (DDI) numbers, complete ranges, campaign lines and out-of-hours routes. A number with little recent traffic may still be printed on a contract or used for an important callback.
| Record | What to Gather |
|---|---|
| Identity and Ownership | Number or range, main billing number where applicable, current provider, account reference and authorised account holder. |
| Provider Records | Installation or service address and postcode, billing address where relevant, and the details the gaining provider requires for this order. |
| Current and Future Routing | Department, extension or queue; business-hours and closed-hours destinations; intended destination after migration. |
| Dependencies | Linked broadband, fax, alarms, lift or door-entry equipment, forwarding, published contact details and any other service sharing the account or line. |
| Decision and Evidence | Keep, move or separately review; criticality; evidence location; provider validation; owner and unresolved action. |
Ask equipment suppliers to confirm the migration route for alarms, entry systems and other non-voice devices. A successful voice call does not prove that an attached device works. The PSTN switch-off readiness guide covers the wider inventory and dependency work.
Prepare the SIP Number Porting Checklist
Ofcom’s number-portability guidance explains the ability to retain numbers when changing provider. Your migration still needs a validated order and agreed operational steps.
Give the gaining provider the reconciled inventory and ask it to confirm the required account evidence and authorisation, which numbers can move together, and whether any range must be handled as a unit. Do not assume you can pilot one DDI from a range: the OTA Number Porting Quick Start Guide notes that splitting a range may not be technically possible.
Before accepting a change window, get written answers to these questions:
- Has the order been validated, and which details or dependencies remain unresolved?
- What services could cease or change when these numbers move?
- Who deals with a rejection, and how will we receive an updated plan?
- Which activation process applies, and when does the provider need our final go/no-go decision?
- What happens if the order is delayed or only some inbound routes work?
Keep cancellation separate from porting. Agree the sequence with the providers before ceasing anything. A requested date, an accepted order and successful activation are different milestones; none should be substituted for another on the change sheet. Industry process timings are not a promise of your port date.
Plan SIP Trunk Capacity Around Simultaneous Call Legs
For SIP trunk capacity planning, gather peak simultaneous inbound and outbound usage from PBX or provider records. Daily call totals and staff numbers do not tell you how many calls overlap. Ask whether failed attempts appear in the data: a service already hitting its limit may hide unmet demand.
Choose an observation period that includes your meaningful busy periods, such as a campaign or seasonal peak, and record its dates. If reliable records are unavailable, label the initial estimate and arrange monitoring before treating it as an established requirement.
Check What the Provider Counts
Ask how capacity is shared between directions and sites, whether queued calls occupy channels, and how external forwarding, transfers and conferences are counted. Distinguish a conversation from its external call legs. The answer depends on the routing and commercial model.
Hypothetical example: suppose a design must support 12 ordinary external calls at once and four incoming calls simultaneously forwarded back out to mobiles. If the provider counts both external legs of each forwarded call against the same limit, the working requirement is 12 + (4 × 2) = 20 concurrent call legs, before any separately agreed headroom. If forwarding is handled differently, that calculation changes. This is an illustration, not a recommended channel count or a measured business finding.
Document the normal requirement, the busy-period assumption and the degraded-service requirement. If a backup route can support only selected teams, decide which queues or outbound uses take priority. Confirm overflow behaviour, call-attempt limits where applicable, capacity-change procedures and any charges or commitments.
Assess the Actual Connection
Ask the technical team to calculate bandwidth in each direction using the selected codec, packetisation and protocol overhead, including any tunnel or encryption overhead. Assess competing traffic and the backup path too. A headline download speed is not a complete voice design.
Agree call-quality acceptance criteria with the provider for the actual deployment, then test under representative load. RFC 3550’s RTP reporting specification describes packet-loss and interarrival-jitter reporting. It provides measurement context, not a universal pass threshold for every SIP service. Record the measurement point, units and interval alongside the result.
Prove Resilience One Failure at a Time
A backup connection is only one part of continuity. Trace the dependencies from the handset through the switch, router, firewall, SBC and PBX to the provider. Ask whether primary and backup access share power, equipment, a physical route or the same provider platform. Record what is genuinely independent and what remains shared.
| Fault | What to Prove | Recovery Check |
|---|---|---|
| Primary Access Lost | Where new inbound calls arrive; whether authorised users can dial out on the backup; usable capacity. | How routing returns, and whether another intervention is required. |
| PBX or SBC Unavailable | Whether an alternative destination is triggered without relying on the failed device. | Restored registration or routing, queues and number presentation. |
| Site Power Lost | Which equipment remains powered, for the agreed duration, and which alternative remains usable. | Equipment restart order and successful inbound and outbound calls. |
| Provider-Side Fault | Documented alternatives and their platform dependencies; provider support and escalation. | Provider-confirmed restoration and end-to-end checks. |
For each scenario, separate new calls from calls already in progress. Rerouting a new call does not prove that an active call survives. Also separate inbound forwarding from outbound continuity. Agree authorised fault simulations and restoration steps with the technical owners; do not interrupt live equipment without a controlled change plan.
For the wider access design behind these voice checks, use our internet failover checklist for small and multi-site businesses to document backup paths, shared dependencies, switching rules and application-level acceptance tests.
If test calls expose registration or one-way audio problems, use the SIP ALG troubleshooting guide to investigate the voice path with your provider.
Confirm Emergency Calling and Power Arrangements
Ask the provider to document 999 and 112 support, the location information associated with sites or numbers, the update process when equipment or users move, and any limitations on backup routes. Include remote users if they are part of the design.
Ofcom’s emergency-access guidance addresses providers’ obligations as calls move to broadband. It does not tell you which backup equipment or continuity arrangement is included in a particular business SIP contract. Get those responsibilities and limitations in writing.
Check the complete power chain, including access equipment and powered switches, rather than the handset alone. Agree an accessible emergency fallback and staff instructions. Use the provider’s authorised validation procedure; do not place unarranged test calls to emergency services.
Test Business Call Journeys Before and After Porting
For a Teams destination, also test missed queue calls and callback follow-up. Confirm that the right people can find the record after abandonment, voicemail or a transfer to another queue. Include the greeting itself: our auto-attendant script examples and testing checklist help check menu keys, closures and unanswered-call messages.
Where the provider and PBX support it, use temporary numbers or a parallel configuration to test before the live port. Agree how test calls are kept separate from production routing. That can prove configuration readiness, but it cannot prove final routing of a number that has not moved yet.
Use a test record containing the case, number or route, configuration, expected result, actual result, timestamp and time zone, tester, evidence and defect owner. Avoid recording credentials in the worksheet; keep call records and diagnostics in an approved location.
| Test Case | Acceptance Evidence |
|---|---|
| Inbound Numbers | Every critical number reaches its intended destination from agreed external networks. All numbers receive a documented routing check; any sampling has an explicit scope and reason. |
| Outbound and Caller ID | Agreed destination types connect with two-way audio and authorised number presentation; a return call reaches the correct route. |
| Reception and Queues | Menu choices, queue treatment, hold, attended and unattended transfers, voicemail, closed-hours and overflow follow the agreed call flow. |
| Keypad Input and Special Uses | DTMF works in the actual receiving menus. Required fax or device workflows have separate supplier-approved tests. |
| Load and Limits | Representative concurrency works; quality meets agreed criteria; capacity-limit behaviour is understood and recorded. |
| Failure and Restoration | Controlled scenarios record new inbound calls, outbound calls, active-call behaviour, backup capacity and return to the primary route. |
| Emergency Arrangements | Provider-approved verification of routing, location records, limitations and fallback instructions is complete. |
Keypad signalling deserves its own row. RFC 4733 specifies RTP carriage of telephone events, including DTMF. Confirm the negotiated method and test the real menu. Clear speech does not establish that “press 1” works.
Check security settings alongside the call tests: authentication, provider-approved firewall and NAT rules, administrative access, destination restrictions and alert recipients. Agree who owns certificate renewal or other time-sensitive configuration. An unrestricted temporary rule should not become the accepted configuration simply because it made a test pass.
Write Two Recovery Plans Around the Port Boundary
Before the Numbers Move
Document how to stop the change, restore saved PBX or network configuration, and keep the existing route available where the agreed design allows it. Confirm provider deadlines for changing or cancelling an activation. Technical readiness should be reviewed before those deadlines, not when everyone joins the cutover call.
After the Numbers Move
Ask what can actually be recovered after activation: corrected routing on the gaining service, an agreed alternative destination, or a provider-led restoration process. Returning local PBX settings does not itself return inbound number routing to the losing provider. Do not write “roll back the port” unless the providers have confirmed the process, availability and responsibilities for this order.
The OTA guide distinguishes changes and cancellation before activation from the activation that redirects inbound traffic. Use that boundary to make your recovery plan specific, without assuming a standard restoration time.
Set explicit triggers for holding the change or invoking recovery: a critical number misroutes, essential outbound calling fails, emergency arrangements remain unresolved, or an agreed quality test fails. Name the decision-maker, escalation contact, next review time and staff communication route. The fallback must also explain any reduced capacity or functionality.
If the migration also needs a new access connection, use the business broadband checklist to confirm upload requirements, IP addressing, support boundaries and backup behaviour before ordering.
Use a Source-Linked Go/No-Go Verification Matrix
For each row, record confirmed, conditional, unresolved or not applicable, with a reason, owner, evidence location and check date. Public sources explain why a question matters. Your provider records, configuration and tests establish whether your migration is ready.
| Gate | Evidence to Retain | Reference and Verification Route |
|---|---|---|
| Numbers and Porting | Reconciled inventory, provider-validated order, range handling and linked-service decisions. | Ofcom portability; OTA process guide; order-specific confirmation. |
| Configuration and Capacity | Supported versions, call-leg assumptions, busy-period data, bandwidth design and overflow results. | SIP standard; actual support documentation and load tests. |
| Quality and Call Flows | Route checks, two-way audio, caller ID, transfer, menu and quality results against agreed criteria. | RTP reporting; DTMF events; deployment-specific tests. |
| Resilience and Emergency Access | Dependency map, controlled failure/restoration results, location verification and fallback instructions. | Ofcom emergency-access context; provider-approved business arrangements. |
| Cutover and Recovery | Decision authority, activation milestone, pre-port stop plan, post-port recovery and escalation contacts. | OTA activation context; written change plan. |
A conditional item needs an agreed condition and someone accountable for closing it. An unresolved critical route, emergency arrangement or recovery dependency should hold approval until resolved. This is a practical decision framework, not a certification or a substitute for the technical owners’ sign-off.
Close the Migration With Evidence
Repeat live-number checks after activation and review the first meaningful busy period. Monitor rejected calls, channel use, quality reports and specific user examples. Ask for the time, number, direction and observed behaviour when someone reports a fault.
Retain the final number list, routing, capacity, accepted test results, support contacts and configuration ownership. Reconcile the first bills and agree closure of old services only after the providers confirm the sequence and dependencies. Schedule resilience retests after material routing, access, PBX or site changes.
If you are still comparing suppliers, use the SIP trunking buyer’s guide to request written answers before turning the proposal into a migration plan.
Download the SIP Trunking Migration Checklist
The four-page printable worksheet brings together the number inventory, capacity assumptions, failure checks, test record and cutover decision. Use it with your provider’s own order documents and technical test plan.
PDF · 4 PAGES
Your SIP Migration Checks, in One Working Record
Record evidence, owners and open actions before approving the move.
Download the Migration Checklist
Opens the PDF in a new tab.
About This Checklist
This is an editorial planning tool built from Ofcom guidance, OTA industry process documentation and IETF specifications reviewed on 8 October 2026. It adds deployment-specific evidence gates and separates recovery before and after number activation. It is not a survey, a tested provider comparison or a promise of compatibility, capacity, uptime or uninterrupted migration. Recheck the documents applicable to your order before cutover.
Frequently Asked Questions
What Information Do We Need Before a SIP Migration?
Gather a reconciled number and range inventory, account records, current and intended call routing, PBX versions and licences, peak simultaneous usage, connectivity and power dependencies, emergency-calling arrangements and named technical owners. Resolve these into a provider-confirmed order, test plan and recovery plan.
Can We Test SIP Trunking Before Porting Our Numbers?
Where the provider and phone system support it, temporary numbers or a parallel configuration can test call flows before porting. Confirm how tests are isolated from live routing. Repeat live-number tests after activation, because a temporary number does not prove final routing of your ported numbers.
How Many SIP Channels Should We Order?
Use meaningful busy-period concurrency and the provider’s rules for external call legs, queues, forwarding and transfers. Record any headroom assumption, backup-route capacity and overflow behaviour. Staff headcount and daily call totals are not sufficient on their own.
Can We Move One Number From a DDI Range First?
Do not assume so. Ask the gaining provider to confirm whether the range can be split and what happens to the remaining numbers. The OTA porting guide notes that a requested range split may not be technically possible, so agree the migration grouping before booking a pilot.
Can a Completed Number Port Be Rolled Back Immediately?
Do not rely on immediate reversal. Restoring local phone-system settings does not itself restore inbound number routing to the losing provider. Get order-specific recovery arrangements from the providers, including alternative routing, escalation and any restoration process.
Should We Cancel the Old Service Before the Port?
Agree the porting and cancellation sequence with the providers first. Check linked broadband and other services before ceasing anything. After activation, verify the live routes and confirm the remaining dependencies before closing old services.
How Do We Check Emergency Calling During Migration?
Use the provider’s authorised validation procedure to check emergency routing, location records, backup-route limitations and staff fallback instructions. Do not make unarranged emergency test calls. Retain the verification result and responsibility for future location updates.
Join The Conversation
If keypad tones fail on some menus but speech is fine after a SIP migration, what's the usual culprit and where do you start?
Nearly always a DTMF relay mismatch rather than an audio fault, since tones travel separately from speech. Check which method each side negotiated — RFC 4733 telephone-event, inband audio or SIP INFO — and that the payload type matches across PBX, SBC and provider. If inband is used, a compressed codec or transcoding can destroy the tones, so align the method end to end and retest the real menus.
If an alarm or door-entry unit still expects an analogue line, should we use an ATA or replace it with an IP or mobile communicator?
Ask the alarm monitoring company and insurer first. Monitored alarms usually need an approved IP or dual-path mobile communicator; an ATA over VoIP is unsupervised and modem-style signalling can fail. A basic door-entry dialler may work on an ATA if the supplier confirms it and you test real calls, including power loss. Check what else depends on the line before ceasing it.